MODEL PROFILE
Signal or code
Error codes and display signals
The official manual linked for this model documents these messages. Some indicators apply only to variants that display them; each entry is labeled as a code, indicator, or status.
No matching signal for this model.
Model and error-code facts may be shown in the language of the original source.
Official PDF manual
Jump to manual pages
Open the official PDF at pages that document signals for this model.
MODEL OVERVIEW
About this model: GE PSS26NHPWW
White Profile PSS26NHPWW with in-door Refreshment Center, interior CustomCool and documented Door Alarm.
Exact white Profile and two access systems
PSS26NHPWW identifies a white-on-white GE Profile side-by-side refrigerator with 25.50 cubic feet of total stated storage: 16.02 cubic feet for fresh food and 9.48 for the freezer. The exact GE record gives a 35 3/4 inch width, 34 11/16 inch depth and 69 1/4 inch height. Its distinctive Refreshment Center is in-door access to frequently reached drinks and foods; GE describes that convenience on this exact product page. The separate CustomCool feature belongs to an interior sliding pan used for selected chilling or thawing tasks, not the door access hatch. Those two names can be confused because both concern beverages, but they identify physically different parts. This retail SKU also specifies an upfront electronic digital temperature display and an integrated ice system. Its linked PDF is a broad Models 23, 25, 26, 27 and 29 manual, so exact features are assigned from the GE PSS26NHPWW product listing and their behavior is checked on the relevant rendered manual pages.
Door Alarm on the verified dispenser
The exact product specification includes Door Alarm on the dispenser. Page fifteen of its owner guide tells the user to press the alarm pad until its indicator comes on; with the option enabled, a sound begins when either door has remained open more than three minutes. Closing the door turns off the light and stops beeping. It is a specific open-door warning, not a report that the ice maker, compressor or CustomCool pan has failed. If it sounds while the cabinet appears shut, first move packages away from the door path, check both door seals and close both sides firmly. The refreshment hatch is part of the refrigerator door assembly, so check that access point too without calling it the CustomCool drawer. Note whether the indicator was enabled, which access point had been used, the time before the beep and whether closing ended it. A Water Filter Indicator Light is separately specified for this model; it reports cartridge upkeep rather than a door problem.
CustomCool, storage and control states
CustomCool's interior pan has ExpressChill, ExpressThaw and SelectTemp choices in the exact specification. Page seven explains that selecting a function lights SET and that ExpressChill or ExpressThaw shows a countdown; those are ordinary settings and time displays. The pan is sealed and uses its own air and temperature components. They should not be interpreted as Door Alarm or fault codes. The in-door Refreshment Center, by contrast, provides shorter access to favorite items; the installation chapter even distinguishes the electrical harnesses of refreshment-center doors. Four sliding freezer baskets, including three full-extension baskets, and a Quick Space fresh-food shelf give this 25.5 cubic foot cabinet several rearrangement points. After moving a shelf, basket or tall beverage container, check that nothing projects into a gasket or blocks the door's final travel. GE also lists Quick Ice at the dispenser, so ice production and a prolonged open-door tone should be described as separate control subjects.
Temperature and filter follow-up
The linked guide starts the refrigerator and freezer controls at 37 F and 0 F and advises allowing twenty-four hours for temperature stabilization after adjustment. A door left open long enough to trigger Door Alarm can bring warm room air into the compartments; do not judge cooling by a single reading taken immediately after closing it. The water filter is in the upper right of the fresh-food section. Page nine says its dispenser indicator turns orange for replacement soon and red when the cartridge should be replaced, with reduced flow another reason to replace it. That sequence is filter maintenance, unlike the audible three-minute door warning. If the door alert recurs, report the exact white PSS26NHPWW suffix, whether the Refreshment Center or either main door was accessed, time to sound, seal contact, shelf positions and whether the beep stops on closure. If temperature or water flow remains abnormal after normal checks, describe those symptoms separately to qualified service rather than inventing an undisclosed numeric error for this family manual.
Verified model details
Exact SKU specifies both the in-door Refreshment Center and interior CustomCool.
Source for this detailEnabled Door Alarm sounds when either main door is open over three minutes.
Source for this detail · Source page: 15
This description summarizes the linked source documents; check each cited source for your exact model and region.
Manufacturer source
Open official source
GE Profile™ 25.5 Cu. Ft. Side-by-Side Refrigerator with Refreshment Center - PSS26NHPWW - GE Appliances
Open official sourceIf there is a safety risk, stop using the appliance and follow the manufacturer’s instructions.