Water heater / GE

PF40S10FPY

Find the official source for this exact appliance model.

Signal or code

Error codes and display signals

The official manual linked for this model documents these messages. Some indicators apply only to variants that display them; each entry is labeled as a code, indicator, or status.

F10Error codeLower heating element failure.F20Error codeLower heating element failure.F11Error codeUpper heating element failure.F21Error codeUpper heating element failure.F14Error codeCompressor failure or excessive discharge temperature.F15Error codeFan failure.F16Error codeNo hot water: the mixing-valve outlet safety cutoff tripped.F17Error codeNo hot water: the mixing-valve outlet safety cutoff tripped.F18Error codeIntegrated mixing valve failure.F63Error codeIntegrated mixing valve failure.F19Error codeUncontrolled heating source detected.F30Error codeTank temperature sensor T1 has an open or short circuit.F31Error codeTank temperature sensor T2 has an open or short circuit.F32Error codeTank temperature sensor T1 or T2 failure.F34Error codeEvaporator inlet temperature sensor T3a failure.F35Error codeEvaporator outlet temperature sensor T3b failure.F36Error codeCompressor outlet temperature sensor T4 failure.F37Error codeAmbient temperature sensor T5 failure.F38Error codeMixing-valve outlet temperature sensor T6 failure.F39Error codeMixing-valve cold-inlet temperature sensor T7 failure.F41Error codeThe sensing anode may be miswired, or the tank may be empty.F43Error codeThe leak-detect module reports water near the heater.F42Error codeCondensate sensor failure.F46Error codeEvaporator is not frost-free; the refrigerant may be leaking or defrost may have failed.F53Error codeEvaporator is not frost-free; the refrigerant may be leaking or defrost may have failed.F47Error codeSealed refrigeration system vapor-lock fault.F48Error codeAmbient temperature is outside the heat-pump operating range.F49Error codeControl board reports excessive temperature.F50Error codeInverter fault.F51Error codeInverter software fault.F52Error codeCompressor discharge temperature is too low.F54Error codeSuperheat is too low; refrigerant may be leaking.F55Error codeElectronic expansion valve is outside its expected range; refrigerant may be leaking.F56Error codeElectronic expansion valve is outside its expected range, or a refrigerant leak test indicates a possible leak.F57Error codeConcurrent electrical loads draw excessive current.F60Error codeAC electrical supply detection fault.F61Error codeTank water temperature is too high.F62Error codeIncoming water temperature is too high.F70Error codeSensing anode is depleted.F73Error codeCondensate drain-pan outlet is blocked.F74Error codeAir filter is dirty; a fault that repeats after cleaning may indicate a refrigerant leak.F75Error codeThe tank is dry or not filled sufficiently.F76Error codePower-supply voltage was too low at startup.F77Error codeA control-panel key is stuck.F78Error codeLeak sensor has detected water.F81Error codeLeak sensor battery is low.F90Error codeE2 module is unplugged or damaged.F91Error codeDataFlash memory fault.F92Error codeDataFlash memory fault.F93Error codeControl board has no personality data.F94Error codeWi-Fi board failure; Wi-Fi icon is dark.F95Error codeCTA communication module software fault.F96Error codeCTA module is disconnected or its battery is low.

Model and error-code facts may be shown in the language of the original source.

Official PDF manual

Jump to manual pages

Open the official PDF at pages that document signals for this model.

MODEL OVERVIEW

About this model: GE PF40S10FPY

GE Profile GeoSpring PF40S10FPY is a 40-gallon, 120-V smart hybrid heat-pump water heater with FlexCapacity. GE lists its cabinet at 59.5 × 24 × 24 in. (H × W × D), useful measurements to check before installation. Its control offers Heat Pump, Hybrid, High Demand, Standard Electric and Vacation modes, which balance energy use and hot-water recovery; on this FlexCapacity model, Normal, High and X-High settings change usable hot-water output through an integrated mixing valve.

Exact model and cabinet

PF40S10FPY is GE's 40-gallon GeoSpring heat-pump model marketed for 120 V with FlexCapacity. GE rates this model at 46 gallons in the first hour and gives it a 3.1 uniform energy factor. Its product sheet also resolves an easily missed electrical point: although sold as a 120-V version, the listed circuits are 120/110 V at 15 A or, after the specified conversion, 240/208 V at 25 A. A first-hour rating measures initial delivery under a standard test; it is not the volume stored in the tank or a promise of the same flow all day. Use the actual installation instructions to decide whether conversion is possible at a particular site.

PF40S10FPY should not be selected solely because it shares the GeoSpring and FlexCapacity names with PH65S10BPY. GE's exact sheets put the PF40 at 40 gallons, 120 V and 59.5 × 24 × 24 inches; the PH65 is 65 gallons, 240 V and 67.125 × 27 × 27 inches. The electrical supply and cabinet opening are therefore separate fit checks, even though both models have the integrated mixing-valve feature. Before considering one as a replacement for the other, compare the rating label, available space, water connections and the relevant installation instructions. A common product-family name does not establish electrical or physical interchangeability.

Source for this detail · products.geappliances.comSource for this detail · products.geappliances.comSource for this detail · products.geappliances.com

FlexCapacity configuration

This PF40S10FPY is a FlexCapacity version. GE's manual describes Normal, High and X-High usable-hot-water settings operated through an integrated mixing valve. This is separate from choosing Heat Pump, Hybrid or another heating mode: one selection concerns delivered hot-water capacity, the other concerns how the tank is heated. Treat the outlet temperature and scald warnings seriously, especially when increasing a setting. The matching FlexCapacity fault list includes mixing-valve and outlet-sensor conditions that should not be transferred to a non-Flex model.

Source for this detail · images.salsify.com · Source page: 9Source for this detail · products.geappliances.com

Heating modes

GE lists Heat Pump, Hybrid, High Demand, Standard Electric and Vacation modes for PF40S10FPY. Heat Pump relies on the heat-pump path, while Hybrid combines heat-pump operation with electric elements when needed; High Demand is aimed at faster recovery when hot-water demand rises. Standard Electric uses the elements instead of the heat-pump strategy. These names describe different operating choices, not five tank capacities. The control-panel and operating-mode pages of the linked manual explain the trade-offs and should be consulted before switching modes to address a temporary shortage.

Source for this detail · images.salsify.com · Source page: 8Source for this detail · products.geappliances.com

Temperature decisions

Tank size alone does not remove the need to manage outlet temperature. For PF40S10FPY, the manual places scald warnings next to the operating instructions and explains the role of the temperature setting. Higher settings may affect usable hot water, but they also increase burn risk, so the choice must take the people using the taps into account. Distinguish a temperature preference from a heating fault: an F-code on the display calls for its own manual entry, even if the water feels cooler than expected.

Source for this detail · images.salsify.com · Source page: 4Source for this detail · products.geappliances.com

Filters and tank care

In Heat Pump, Hybrid and High Demand operation, PF40S10FPY moves air through three filters. GE says the Filter indicator illuminates when they need attention; the manual describes removing, cleaning, drying, reinstalling and resetting the filters. A clogged filter can reduce effective heat-pump operation, so the indicator is a maintenance cue rather than a compressor diagnosis. The same care section describes the condensate drain; a blockage there has a separate alarm. Use the cited procedure and keep electrical parts dry during routine care.

Source for this detail · images.salsify.com · Source page: 13Source for this detail · products.geappliances.com

Interpreting fault codes

The FlexCapacity diagnostic table for PF40S10FPY separates heating faults from mixing-valve faults. F10 and F20 concern the lower electric element; F11 and F21 concern the upper one. F16 or F17 can follow a mixing-valve outlet safety cutoff, and F18 or F63 describes integrated mixing-valve failure. The same code list includes tank and outlet temperature sensors, so a temperature complaint is not one single diagnosis. Read the full code and the linked manual table before arranging service; internal electrical and valve repair is not a routine owner check.

Source for this detail · images.salsify.com · Source page: 32Source for this detail · products.geappliances.com

Verified model details

This description summarizes the linked source documents; check each cited source for your exact model and region.